Deadweight Tester

Pressure Balance

Model LR-Cal LDW-P

Deadweight Tester / Pressure Balance (Primary Pressure Standard), pneumatic, Ranges from -0,03...-1 bar to 0,4...100 bar and -0,435...-14 psi to 5,8...1500 psi.

Total uncertainty of measurement: ±0.008% or ±0.015% of measured value.

 

Applications:

 

  • Primary standard for defining the pressure scale in a range up to 100 bar pneumatic
  • Reference instrument for calibration laboratories and factory for the testing, adjustment and calibration of pressure measuring instruments
  • Self-contained, complete, stand-alone system, also suitable for on-site use

Special features:

 

  • Total measurement uncertainty down to 0.008% of measured value
  • Factory calibration includes traceability to national standards, as standard. Optional with DKD/DAkkS calibration
  • High long-term stability with recommended recalibration cycle every 5 years
  • Masses manufactured from stainless steel and aluminum, local gravity adjustment possible at no additional charge
  • The optional quick-change system of piston-cylinder system enables fast and secure exchange of the piston-cylinder system in order to change the measuring range without tools.

Technical data of model LR-Cal LDW-P

 

Pressure range 1)

bar

-0.03...-1

0.03...2

0.2...10

0.4...50

0.4...100

 

Required weights

kg

5

10

10

10

20

 

Smallest step 2)

bar

0.01

0.01

0.05

0.25

0.25

 

Nominal cross-sectional area of the piston

cm²

5

5

1

0.2

0.2

 

Pressure range 1)

psi

-0.435...-14

0.435...30

2.9...150

5.8...500

5.8...1000

5.8...1500

Required weights

kg

5

10

10

7

13

20

Smallest step 2)

psi

0.1

0.2

1

5

5

5

Nominal cross-sectional area of the piston

cm²

5

5

1

0.2

0.2

0.2

Genauigkeit 3)

 ±0.015% of measured value (optional: ±0.008% of measured value)

Version

for ranges up to 10 bar

integrated pressure source (priming pump and spindle pump)

for ranges from 20 bar, and Vacuum

Pressure port for external pressure or vacuum supply

Connections / Media

Connection piston-cylinder system

M20 x 2 male thread; Optional: quick-connector (required for Vacuum range)

Connection for test item

Quick connector 1/2" BSP female thread as standard, freely rotating, changeable (for other threaded inserts, see accessories)

Pressure transmission medium

clean dry non-corrosive gases (e.g. air or nitrogen)

Connection for external pressure/vacuum supply

6 mm SWAGELOK (R) tube fitting; max. 110% of the assigned measuring range; Only for pneumatic high-pressure version)

Materials

Piston

Tungsten Carbide

Cylinder

Tungsten Carbide

Set of masses

Stainless steel 1.4305 and aluminum, non-magnetic

Piping in instrument base

Low-pressure version: flexible hose from polyurethane, 4 x 0.75 mm
High-pressure version: stainless steel 1.4571, 3 x 1 mm

Operating conditions

Operating temperature

°C

18...28

Weight

Instrument base

kg

18.0 (19.0 incl. optional quick connector)

Piston-cylinder system

kg

1.5 (5.7 incl. bell jar and aluminum plat in optional storage case)

BAR vacuum mass set

kg

13.1 (incl. piston-cylinder system in storage case)

BAR basic mass set

kg

16.2 (incl. storage case)

BAR mass set extension

kg

14.0 (incl. storage case)

PSI vacuum mass set

kg

13.0 (incl. piston-cylinder system in storage case)

PSI basic mass set

kg

12.5 (incl. storage case)

PSI mass set extension 1

kg

11.0 (incl. storage case)

PSI mass set extension 2

kg

18.5 (incl. storage case) only for pressure range 1,500 psi

Dimensions

Instrument base

mm

W 400 x D 375 x H 265

Storage case for basic mass set

mm

W 400 x D 310 x H 310

Storage case for mass set extension

mm

W 215 x D 310 x H 310

Optional storage case for piston-cylinder system

mm

W 300 x D 265 x H 205

Certificate

Calibration

Factory certificate of calibration, traceable. Optional: DKD-/DAkkS certificate

 

Ø      Theoretical starting value; corresponds to the pressure value generated by the piston (by its own weight). To optimize the operating characteristics more weights should be loaded.

Ø      The smallest pressure change value that can be achieved based on the standard weight set. To reduce this, a set of trim masses is also available.

Ø      The accuracy from 10% of the measuring range is based on the measured value. In the lower range, a fixed error based on 10% of the range applies.

Ø      Measuring uncertainty assuming reference conditions (ambient temperature 20°C, air pressure 1,013 mbar, relative humidity 40%). For operation without an Intelligent Calibration Modulel LR-Cal IKM corrections mus be made if required.

 

Scope of Delivery and Options for model LR-Cal LDW-P

Scope of delivery:

 

  • Base with adjustable feet
  • Priming pump (not for high-pressure and vacuum version)
  • Spindle pump for pressure generation and fine adjustment
  • Piston connection with M30 x 2 male threads
  • Quick connector for test items with 1/2" BSP female threaded insert, changeable
  • Piston-cylinder system with bell jar
  • Basic mass set in carrying case
  • Mass set extension in carrying case (dependent on the measuring range)
  • Set of masses manufactured to standard gravity (9.80665 m/s²)
  • Manual in English and German language
  • Factory calibration certificate, traceable to national standards

Options:

 

  • Piston connection with quick-release connector (necessary for vacuum range)
  • System with increased accuracy to 0.008%
  • Set of masses manufactured to local gravity
  • Fine increment weights
  • Storage case for piston-cylinder system
  • DKD/DAkkS or UKAS calibration certificate

Accessories for model LR-Cal LDW-P

 

Order-Code

Description

LDW-FMS-F1

The weights included in the standard scope of delivery are ideally suited for everyday use. If you would like to generate intermediate values, however, we recommend using a set of trim-masses.

Set of trim-masses, class F1
(1 x 50 g, 2 x 20 g, 1 x 10 g, 1 x 5 g, 2 x 2 g, 1 x 1 g,
1 x 500 mg, 2 x 200 mg, 1 x 100 mg, 1 x 50 mg,
2 x 20 mg, 1 x 10 mg, 1 x 5 mg, 2 x 2 mg, 1 x 1 mg

LDW-FMS-M1

Set of trim-masses, class M1
(1 x 50 g, 2 x 20 g, 1 x 10 g, 1 x 5 g, 2 x 2 g, 1 x 1 g,
1 x 500 mg, 2 x 200 mg, 1 x 100 mg, 1 x 50 mg,
2 x 20 mg, 1 x 10 mg, 1 x 5 mg, 2 x 2 mg, 1 x 1 mg

CPB5000-ADS

As a standard, the deadweight tester / pressure balance is equipped with a quick connector for connecting the test item. For this purpose, various threaded adapters, which can be easily exchanged, are available. Additionally the sets of adapters include spare O-rings as well as a spanner, 32 flats and 14 flats, for exchanging the adapters.

Set of adapters: 1/4" BSP, 3/8" BSP, 1/2" NPT, M20 x 1.5

CPB5000-ADS-NPT

Set of NPT adapters: 1/8" NPT, 1/4" NPT, 3/8" NPT, 1/2" NPT

CPB5000-WA90

Angle connection 90°, for test specimens with back mounting connection

CPB5000-TV-1000

Purifier (without diaphragm), max. 1,000 bar, designed for measuring instruments (test items) where the fill fluid should not come into contact with the deadweight tester / pressure balance.

CPB5000-R-SET

Set of O-rings (5 pcs. 8 x 2 and 5 pcs. 4 x 2.2) for piston connector and test item connector

CPB5000-PN-RS

Cleaning setr LR-Cal LDW-P piston-cylinder system